    Cataract

    FCI Ophthalmics is a world leader in the development of state-of-the art surgical devices for cataract surgery. The company has also obtained the rights to distribute surgical devices from such reputable manufacturers as Morcher and Geuder. From iris hooks and capsular tension rings to pupil dilators and a full range of other cataract surgery devices, your can trust FCI Ophthalmics to be your complete provider.

    To learn more about the latest cataract surgery devices, contact FCI Ophthalmics.

    Morcher Capsular Tension Rings

    FCI Ophthalmics is the exclusive U.S. distributor of Morcher capsular tension rings. Morcher capsular tension rings are used during cataract surgery to stabilize the capsule, and they have undergone extensive clinical testing in the United States. Three rings with different diameters to accommodate patients’ individual capsular bags have been approved by the FDA for commercial distribution.

    MR-1400 Type 14 PMMA

     

         Axial length <24mm for normal eyes


    MR-1410 Type 14A PMMA

     

         Axial length >28mm for highly myopic eyes


    MR-1420 Type 14C PMMA

     

         Axial length 24-28mm for normal or myopic eyes

    Indications

    • Missing or damaged zonules
    • Lens subluxation
    • Pseudoexfoliation
    • Myopia
    • Zonulolysis
    • Soft IOL
    • Marfan’s Syndrome

    Advantages

    • Circular expansion of capsular bags
    • Stablizes conditions during surgery
    • Improves IOL centration
    • Reduces risk of capsular fibrosis
    • Resists capsular shrinkage

      

    Download Reimbursement Guidelines for Capsular Tension Rings
    Download Medicare Reimbursement Guidelines for Capsular Tension Rings

     

    Back to Top

     

    Geuder Capsular Tension Ring Injector

    This reusable injector is designed for the clockwise, one-handed implantation of the Morcher capsular tension rings.

    G-32955 Reuseable Injector for the Capsular Tension Ring

    Download instructions for loading, cleaning, and sterilizing the Geuder Injector

     

    Back to Top

     

    Rumex Capsular Tension Ring Injector

    This reusable injector is designed for the clockwise, one-handed implantation of capsular tension rings.

    16-253 Reuseable Injector for the Capsular Tension Ring

     

    Back to Top

     

    EyeJet

    The Eyejet from FCI Ophthalmics is a preloaded capsular tension ring on a disposable injector for cataract surgery.

    • Order right from order numbers below for clockwise insertion
    • Order left from order numbers below for counterclockwise insertion

    MR-14 Right
    MR-14 Left
    MR-14A Right
    MR-14A Left
    MR-14C Right
    MR-14C Left
    MR-10C Right
    MR-10G Right Preloaded Type 14 CTR
    Preloaded Type 14 CTR
    Preloaded Type 14A CTR
    Preloaded Type 14A CTR
    Preloaded Type 14C CTR
    Preloaded Type 14C CTR
    Preloaded Henderson CTR
    Preloaded Malyugin/Cionni CTR

     

     

     

    See a video of the Malyugin/Cionni CTR on EyeTube.

     

     

    Back to Top

     

    Cionni Capsular Tension Rings

    Designed by Morcher and distributed by FCI Ophthalmics, Cionni Capsular Tension Rings are used to stabilize the capsular bag in cases of damaged or missing zonules. These devices for cataract surgery are specifically designed for scleral fixation with suture.

    • Designed by Robert J. Cionni, M.D.
    MR-1L
    MR-2C
    MR-2L
    MR-1G Type 1L
    Type 2C
    Type 2L
    Type 1G 11 mm
    11 mm
    11 mm
    10 mm

     

     

    Material: PMMA, Box of 1, sterile

    Indications

    Cionni Capsular Tension Rings are used to stabilize and recenter the capsular bag in the following cases:

    • Missing or damaged zonules larger than 4 clock hours
    • Lens subluxation
    • Pseudoexfoliation
    • Myopia
    • Zonulolysis
    • Soft IOL
    • Marfan’s Syndrome

    Advantages

    • May be fixated to the sclera
    • Promotes circular expansion of capsular bags
    • Stabilizes conditions during cataract surgery
    • Improves IOL centration
    • Reduces risk of capsular fibrosis
    • Resists capsular shrinkage
    • MR-2C may be inserted with Geuder injector (G-32955), drawn up to ¾ of the way only

     

     

    Download Reimbursement Guidelines for Capsular Tension Rings
    Download Medicare Reimbursement Guidelines for Capsular Tension Rings

     

    Back to Top

     

    9-0 Polypropylene Sutures

    The 9-0 polypropylene suture is non-absorbable and particularly useful when used with Cionni Capsular Tension Rings. The sutures are available in two double-armed versions. One has two long, straight needles. The other has one long, straight needle and one short, curved needle.

      Cionni Fixation Securing an IOL
         
    Product # P90062 P9009062
    Suture Length 20 cm suture length 30cm Suture length
    Suture Size 9-0 Suture 9-0 Suture
    Armed Double Armed Double Armed
    Name Straight/Straight Straight/Curved
    Suture Length 20cm 30cm
    Material Polypropylene Polypropylene
    Tip Geometry Spatula Spatula
    Needle1 Length 16mm 16mm
    Needle2 Length 16mm 16mm
    Needle1Curvature straight straight
    Needle2 Curvature straight 90º
    Units 12/box 12/box
    Description This is the 9/0 non absorbable polypropylene double armed suture. It has two straight, 16mm, spatula-tipped needles at each end. The suture is 20cm.  This is the 9/0 non absorbable polypropylene double armed suture. It has one straight, 16mm, spatula-tipped needle and one 16mm curved needle at 90º. The suture is 30cm. 
    Use This suture is used to secure the Morcher Cionni Ring. The needle is threaded through the fixation point on the ring.   This suture is used to secure the haptic of an IOL in order to keep it centered.  

    Back to Top

     

    Iris Retractors

    Iris retractors (also known as iris hooks) are used when a patient has cataracts, contracted pupils, or inoperative floppy iris syndrome. Iris hooks are considered the optimal temporary implants for such conditions. These highly effective iris hooks from FCI Ophthalmics can be used when pharmacological dilation is unsuccessful. By helping to maintain a safe pupillary diameter, iris hooks are, in many cases, invaluable devices for cataract surgery.

    • Stretches and stabilizes the iris during cataract surgery
    • Blue polypropylene
    • Both disposable and reusable options
    S9-5014
    S9-5054
    S9-5116 Disposable
    Disposable
    Reusable in steam autoclavable container 4 per box
    5 sets of 4 per box
    6 per box

     

    Back to Top

     

    Mackool™ Cataract Support System

    FCI Ophthalmics has been awarded distribution rights for the Mackool™ Cataract Support System. The system is one of the many other systems and devices for cataracts surgery provided by FCI. The Mackool™ Cataract Support System helps provide capsular support during cataract surgery for patients who have contracted pupils or floppy iris syndrome.

    • Designed by Dr. Richard J. Mackool, M.D.
    • Flexible / Disposable
    • Easy Insertion / Removal
    MH-1005 PMMA Box of 5, sterile

     

     

     

    Back to Top

     

     

    Ring Calipers

    Ring calipers from FCI Ophthalmics are used during cataract surgery and serve as templates to create a more precise anterior capsulorhexis.

    • PEMA (Polyethelmethacrilate)
    RC-5
    RC-6 5 mm inner diameter
    6 mm inner diameter

     

    Back to Top

     

    Morcher Pupil Dilator

    Important among the devices provided by FCI for cataract surgery is the Morcher pupil dilator. The Morcher pupil dilator type 5S is a semi-circular elastic PMMA ring for the expansion of the pupil during photoemulsification. For patients who have cataracts and contracted pupils or floppy iris syndrome, this is the optimal temporary implant.

    • Sterile package for single use only
    • Pupil dilator may be inserted manually or with the Geuder injector
      (G-32970)
    • Important note: Pupil dilator should be implanted only with viscoelastic for
      protection of the corneal endothelium
    • Overall Length: 7.50 mm
    • Pupil size: 5.0–6.0 mm
    • Thickness: 0.15–0.60/0.90 mm

     

    MR-5S Type 5S PMMA

     

     

     

     

     

    Back to Top

     

    Geuder Pupil Dilator Injector

    The Geuder pupil dilator injector is designed for the clockwise one-hand implantation of the Morcher pupil dilator.

    G-32970 Reusable Injector for the Pupil Dilator

     

     

    Back to Top

     

    Henderson Capsular Tension Rings (HCTR)

     

    The Henderson Ring is a special design of the popular capsular tension rings (CTR) manufactured by Morcher GmbH of Stuttgart, Germany.   The Henderson Ring is an open C-shaped loop made of a single piece of Polymethyl Methacrylate (PMMA).  Employing a Morcher propriety process (CFM) in the manufacture, the PMMA has enhanced flexibility and resistance to breakage. The ring performs the same basic function of standard CTRs by stabilizing the capsular bag before, during and after cataract surgery.

     

    The unique design of the Henderson Ring features eight equally spaced indentations spanning the circumference of the ring creating a sinusoidal shape.  The main advantage of this ring is that the new indentations allow for easier nuclear and cortical material removal while still maintaining the desired stretch of the capsular bag.  Once the residual material has been removed from under the indentations the HCTR can be rotated to change positions of the indentations to allow further removal of lense material that was compressed by the indented portion of the HCTR. .

     

    Indications

     

    • Missing or damaged zonules
    • Lens subluxation
    • Pseudoexfoliation
    • Myopia
    • Zonulolysis
    • Soft IOL
    • Marfan’s Syndrome

    Advantages

    • Circular expansion of capsular bags
    • Stablilizes conditions during surgery
    • Facilitates cortical removal
    • Improves IOL centration
    • Reduces risk of capsular fibrosis
    • Resists capsular shrinkage

     

     Material: PMMA, box of 1, sterile  

     

    Back to Top

     

     

    Ahmed Capsular Tension Segment (CTS)

     

    The Ahmed CTS is a modified design of the Cionni capsular tension rings manufactured by Morcher GmbH of Stuttgart, Germany.   The CTS is a partial ring of clear PMMA covering approximately one quadrant with a hole for temporary or permanent fixation. One or more segments may be used as necessary to support the areas of the capsule that have damaged or insufficient zonular support.. Because it is only a segment, placement is easy and atraumatic, even before phaco. There are no sharp points or edges to tear the capsulorhexis and removal is easy. According to Dr. Ahmed, stripping cortex out from under and around the CTS is easy. The CTS can be used even when anterior or posterior capsular tears are present.

     

     

    Indications

    Capsular Tension Segments are used to stabilize and recenter the capsular bag in the following cases:

    • Significant zonular weakness
    • Lens subluxation
    • Pseudoexfoliation
    • Myopia
    • Zonulolysis
    • Soft IOL
    • Marfan’s Syndrome

    Advantages

    • May be used intraoperatively, secured by an iris hook
    • May be fixated to the sclera for permanent support
    • Stabilizes conditions during cataract surgery
    • Improves IOL centration
    • Reduces risk of capsular fibrosis
    • Resists capsular shrinkage

     

    MR-6D
    MR-6E Type 6D,   9.61mm
    Type 6E,   10.14 Material: PMMA, box of 1, sterile

     

    Back to Top

     

    Kitaro Cataract Drylab & Kitaro Cataract Wetlab

    The KITARO© WetLab and DryLab kits are created with the learning surgeon in mind. With both wet and dry lab kits, the beginner can practice techniques repeatedly without the added complication of long preparation times and costly live tissue samples. These tools simulate the stages of cataract surgery using both a wet lab and dry lab environment to allow new surgeons the ability to train repeatedly on basic surgical techniques.

    • Kitaro Dry/Wet Kits

    KITARO Dry/Wet Lab Kit

     

    Precut Sclerocorneal Sheet + Limbus
    Anterior-capsule film (11cmx2.5m)
    Viscoelastic Substance (10cc)
    Artificial cataract lens mixed (3soft-3medium hard)
    Cornea-iris part for Wet Lab

     

    Cornea-iris part for Dry Lab
    Sclera Part
    Mask for Dry lab
    Base plate
    Segmented Plastic Nuclei Artificial lens (3Types)
    Polymer-clay Nuclei in PC cups
    Anterior Capsule Forceps
    Sclera Fixation Forceps
    U/S (I/A) handpieces (for segmented plastic nucleus)
    U/S (I/A) handpieces (for Polymer-Clay nucleus)
    Spatula Hook
    Phaco Chopper
    Mr. Divider's Hook
    Cystotome (21G Needle) with Syringe
    Artificial Cortex, Resin clay in posterior capsule cups and spare clay
    Sclerocorneal Limbus
    CCC-Processed AC film
    KITARO DVD
    Container

     

     

    K-1195
    K-1250
    K-1255
    K-1260
    K-1265
    K-1270
    K-3000

    Speculum
    Desk top magnifying glass w/operating board for Dry lab
    Drain Box for Wet Lab
    Soft nucleus
    Medium hard nucleus
    Very hard nucleus
    Text Book

     

    Back to Top

    Kitaro Complex Case Labs

    For the advanced surgeon, Kitaro has developed two kits for complex surgical procedures. Like the Dry & Wet Lab kits, the Complex Case Labs allow for repeated practice of techniques and procedures with realistic but synthetic materials.
    The Kitaro Complex Case Lab 1 allows a surgeon to practice such complex cases as small pupil management, weak or ruptured zonules, and intraocular lens transcleral fixation. The surgeon may also elect practice phakic IOL insertion with an optional add-on part.
    The Kitaro Complex Case Lab 2 allows a surgeon to practice conventional extracapsular extraction (ECCE) and posterior capsule rupture management.

    • Kitaro Complex Case Labs

    K-6000
    K-7000

    KITARO Complex Case Lab 1
    KITARO Complex Case Lab 2

     

    • Disposable Goods for Complex Case Lab 1

    K-6010
    K-6020
    K-6030
    K-6040
    K-6050
    K-6060

    Cornea for Weak or Ruptured Zonules
    Cornea for IOL Transcleral Fixation
    Cornea for Small Pupil Management
    Sclerocorneal Sheet
    Mock Iris Retractors
    Artificial Nucleus for Weak Zonules

     

    • Reusable Goods for Complex Case Lab 1

    K-1135
    K-1140
    K-1145
    K-6110
    K-6145
    K-1165
    K-6115
    K-6120
    K-1160
    K-1230
    K-6130
    K-6135
    K-6140

    Sclera Part
    Mask
    Base Plate
    Capsular Tension Ring (2 pcs)
    Dry Nucleus (2pcs)
    Sclera Fixation Forceps
    Tying Forceps
    Needle Holder
    Anterior Capsule Forceps
    Cystotome (26G Needle) with Syringe
    Chopper & Paddle Hook (double-ended)
    Sinsky Hook
    Spring Scissors

     

    • Optional Goods for Complex Case Lab 1

    K-6150
    K-1255

    Cornea for Phakic IOL (2 pcs)
    Drain Box

     

    • Disposable Goods for Complex Case Lab 2

    K-7010
    K-7020
    K-6040
    K-7030
    K-7040
    K-7050

    Cornea for ECCE
    Cornea for PCRM
    Sclerocorneal Sheet (30 pcs)
    Sclerocorneal Sheet for ECCE (6 pcs)
    Nucleus for ECCE (6 pcs)
    Nucleus for PCRM (6 pcs)

     

    • Reusable Goods for Complex Case Lab 2

    K-7060
    K-7070
    K-7075
    K-7105
    K-7115
    K-7120
    K-7125
    K-7130

    Base & Mask for ECCE & PCRM
    Sclera for ECCE (2 pcs)
    Sclera for PCRM
    IOL Foldable Forceps
    Westcott Tenotomy Scissors
    Irrigating Vectis
    Pushpull
    Symcoe Cannula

     

    • Optional Goods for Complex Case Lab 2

    K-1255

    Drain Box

     

    Back to Top

    Источник: http://www.fci-ophthalmics.com/cataract